# If the length of a combined footing for two columns l metres apart is L and the projection on the left side of the exterior column is x, then the projection y on the right side of the exterior column, in order to have a uniformly distributed load, is (where is the distance of centre of gravity of column loads _____ ? with Answer - Civil Engineering Mcqs | TestPrep

> Solved MCQ: If the length of a combined footing for two columns l metres apart is L and the projection on the left side of the exterior column is x, then the projection y on the right side of the exterior column, in order to have a uniformly distributed load, is (where is the distance of centre of gravity of column loads _____ ? Correct Answer: D. y = L/2 – (l – ). Verified answer explanation for FPSC, PPSC, MDCAT, NTS, and CSS competitive exam preparation.

---

Tested in Competitive Exams:

- [NTS Test Prep](https://test-prep.blog/exams/nts)
- [FPSC Past Papers](https://test-prep.blog/exams/fpsc)
- [PPSC Solved MCQs](https://test-prep.blog/exams/ppsc)
- [PMDC MDCAT 2026](https://test-prep.blog/exams/mdcat)
- [UET ECAT Prep](https://test-prep.blog/exams/ecat)
- [CSS Central Superior](https://test-prep.blog/exams/css)

- [Civil Engineering Mcqs](https://test-prep.blog/categories/civil-engineering-mcqs)
Difficulty: Challenging 61% Accuracy

# If the length of a combined footing for two columns l metres apart is L and the projection on the left side of the exterior column is x, then the projection y on the right side of the exterior column, in order to have a uniformly distributed load, is (where is the distance of centre of gravity of column loads _____ ?

Direct Answer & Quick Reference

The correct option is **D. y = L/2 – (l – )**.

A. y = L – (l – ) )

B. y = L/2 + (l –

C. y = L/2 – (l + )

D. y = L/2 – (l – ) **(Correct Answer)**

✨ Explain with AI

Verified Key: D. y = L/2 – (l – )
Solved by 1,666+ students

Verified against official examination board answer keys and standard curriculum textbooks.

- [Previous Question In the lever of third order, load W, effort P and fulcrum F are oriented as follows _____ ?](https://test-prep.blog/mcq/in-the-lever-of-third-order-load-w-effort-p-and-fulcrum-f-are-oriented-as-follow-ca9a19fe-75fd-4d80-8d18-176be69511fb)
- [Next Question The minimum width of the fire escape stairs shall be?](https://test-prep.blog/mcq/the-minimum-width-of-the-fire-escape-stairs-shall-be-ceb3ea95-5f4e-4fb6-8f4d-8ac9e07fe45d)

- [Practice More Civil Engineering Mcqs MCQs](https://test-prep.blog/quiz/smart?category=civil-engineering-mcqs)
- [How We Verify Questions →](https://test-prep.blog/editorial-policy)

## Subject Overview

Explore thousands of solved past paper MCQs for Civil Engineering Mcqs categorized with explanations.

- [Browse All Civil Engineering Mcqs MCQs →](https://test-prep.blog/categories/civil-engineering-mcqs)

## Related Questions

- [In the lever of third order, load W, effort P and fulcrum F are oriented as follows _____ ?](https://test-prep.blog/mcq/in-the-lever-of-third-order-load-w-effort-p-and-fulcrum-f-are-oriented-as-follow-ca9a19fe-75fd-4d80-8d18-176be69511fb)
- [The minimum width of the fire escape stairs shall be?](https://test-prep.blog/mcq/the-minimum-width-of-the-fire-escape-stairs-shall-be-ceb3ea95-5f4e-4fb6-8f4d-8ac9e07fe45d)
- [Choose the wrong statement _____ ?](https://test-prep.blog/mcq/choose-the-wrong-statement-e491e2be-fe10-423a-bc52-050164ea8df3)
- [Choose the wrong statement?](https://test-prep.blog/mcq/choose-the-wrong-statement-ea614ffe-412d-4f02-8d4a-cf59e3d234f6)
- [Choose the wrong statement?](https://test-prep.blog/mcq/choose-the-wrong-statement-fb5efa74-16e8-4f91-a432-96772f86c0ee)

---
*Source: https://test-prep.blog/mcq/if-the-length-of-a-combined-footing-for-two-columns-l-metres-apart-is-l-and-the--194e2974-4f40-4a5b-a4fd-5f8feb81c788*