# Pick out the wrong statement about the design of a sieve plate column ? with Answer - Chemical Engineering Mcqs | ExamZone

> Solved MCQ: Pick out the wrong statement about the design of a sieve plate column ? Correct Answer: D. Minimum recommended downcomer residence time for the disengagement of entrained vapour is the same for both foaming and non-foaming liquids, which is about 20 seconds. Verified answer explanation for FPSC, PPSC, MDCAT, NTS, and CSS competitive exam preparation.

---

Tested in Competitive Exams:

- [NTS Test Prep](https://test-prep.blog/exams/nts)
- [FPSC Past Papers](https://test-prep.blog/exams/fpsc)
- [PPSC Solved MCQs](https://test-prep.blog/exams/ppsc)
- [PMDC MDCAT 2026](https://test-prep.blog/exams/mdcat)
- [UET ECAT Prep](https://test-prep.blog/exams/ecat)
- [CSS Central Superior](https://test-prep.blog/exams/css)

- [Chemical Engineering Mcqs](https://test-prep.blog/categories/chemical-engineering-mcqs)
Difficulty: Easy 80% Accuracy

# Pick out the wrong statement about the design of a sieve plate column ?

Direct Answer & Quick Reference

The correct option is **D. Minimum recommended downcomer residence time for the disengagement of entrained vapour is the same for both foaming and non-foaming liquids, which is about 20 seconds**.

A. An increased weir height improves the tray efficiency at the cost of high plate pressure drop; optimum wear height being 40-90 mm for column pressure above atmospheric and 6-12 mm for vacuum columns

B. For segmental downcomers, the chord length is 60-80% of the column diameter. An initial value of downcomer area of 12% is taken in the design

C. Width of the calming section provided at the inlet and outlet sides of the plate is 75 mm for column diameter below 1.5 metres and 100 mm for larger diameter columns

D. Minimum recommended downcomer residence time for the disengagement of entrained vapour is the same for both foaming and non-foaming liquids, which is about 20 seconds **(Correct Answer)**

Verified Key: D. Minimum recommended downcomer residence time for the disengagement of entrained vapour is the same for both foaming and non-foaming liquids, which is about 20 seconds
Solved by 3,005+ students

Verified against official examination board answer keys and standard curriculum textbooks.

- [Previous Question Which of the following is a type of sedimentary rock?](https://test-prep.blog/mcq/which-of-the-following-is-a-type-of-sedimentary-rock-3c37d9b4-29f3-4b85-8ee8-c30cddad8e31)
- [Next Question Which of the following rock favors petroleum formation?](https://test-prep.blog/mcq/which-of-the-following-rock-favors-petroleum-formation-8de34f5c-5054-406d-81ba-a2b7a775b708)

- [Practice More Chemical Engineering Mcqs MCQs](https://test-prep.blog/quiz/smart?category=chemical-engineering-mcqs)
- [How We Verify Questions →](https://test-prep.blog/editorial-policy)

## Subject Overview

Explore thousands of solved past paper MCQs for Chemical Engineering Mcqs categorized with explanations.

- [Browse All Chemical Engineering Mcqs MCQs →](https://test-prep.blog/categories/chemical-engineering-mcqs)

## Related Questions

- [Which of the following is a type of sedimentary rock?](https://test-prep.blog/mcq/which-of-the-following-is-a-type-of-sedimentary-rock-3c37d9b4-29f3-4b85-8ee8-c30cddad8e31)
- [Which of the following rock favors petroleum formation?](https://test-prep.blog/mcq/which-of-the-following-rock-favors-petroleum-formation-8de34f5c-5054-406d-81ba-a2b7a775b708)
- [DLS stands For_______?](https://test-prep.blog/mcq/dls-stands-for_______-334d51e8-f12a-4948-aae4-0a921c1cabdc)
- [RIH stands for ________?](https://test-prep.blog/mcq/rih-stands-for-________-bb6912da-ac66-4daa-8872-080b0065be37)
- [“The heat capacity of a solid compound is approximately equal to the sum of the heat capacities of the constituent elements.” This is the statement of___________________?](https://test-prep.blog/mcq/the-heat-capacity-of-a-solid-compound-is-approximately-equal-to-the-sum-of-the-h-05c6d5e6-380a-4820-b10d-3ecfd779b04c)

---
*Source: https://test-prep.blog/mcq/pick-out-the-wrong-statement-about-the-design-of-a-sieve-plate-column-a23d476a-0abc-44e7-ad0e-3d3b76da720b*
*Format: Markdown for Agents (Content Negotiation: text/markdown)*